For SPEEDIO Users
Frequently Asked Questions (FAQs)
Below, SPEEDIO users can find FAQs regarding maintenance procedures.
Search by Keyword
Example: Enter a single keyword, such as "replacement,"or "inspection."
Search from List
Maintenance Procedures
-
mt-001
Manual Greasing Method
-
Proper lubrication oil inspection and greasing are required to prevent friction-related wear and to maintain machining accuracy and machine longevity.
Perform manual greasing every 100 km of axis travel after machine installation, or every 3 months or 500 machine operating hours, whichever occurs first.After grease replenishment, move all axes through their full travel range to ensure that the grease is evenly distributed.
View details(PDF 1.6MB)
To avoid personal injury, wear appropriate personal protective equipment (PPE), such as a safety helmet and protective gloves, before performing this procedure.
Each axis (X, Y, and Z) has five grease supply points: four linear guide blocks and one ball screw. Apply grease to all lubrication points during the greasing operation.
-
mt-002
Telescopic Cover Wiper Parts List
-
For detailed information on the Telescopic Cover Wiper Parts List, refer to the PDF below.
View details(PDF 3MB)
-
mt-003
B00 Control All Data Output Procedure
-
This procedure explains how to output all data from the B00 control. Use it as part of your regular maintenance activities.
- Press the NC Power switch to turn ON the NC power.
- Firmly insert the USB memory device into the USB port at an upward angle from below.
- Press the PROGRAM EDIT key, then select External I/O (F3) → Maintenance (F3).
- If necessary, select Disk Format and execute Format (F2).
Formatting is not required if the USB memory device does not contain data of the same format and has sufficient free storage capacity. - Return to the previous screen (F0), then select All Data Output (F1) → Output (F2).
- Wait until the data output process is completed. Do not perform any operations during the process, and confirm that the operation has ended normally.
- Press the RESET key to return to the Manual Conditions screen, then remove the USB memory device by pulling it downward at an angle.
- Connect the USB memory device to a computer and verify that the data has been saved successfully.
- Store the backup data either by:
・Creating a folder for each machine on a computer and saving the data there, or
・Keeping the USB memory device as a dedicated backup device for that machine.
Estimated time required: Approximately 10 minutes.
View details(PDF 2.3MB)
-
mt-004
C00 Control All Data Output Method Procedure
-
This procedure explains how to output all data from the C00 control. Use it as part of your regular maintenance activities.
- Press the NC Power switch to turn ON the NC power.
- Firmly insert the USB memory device into the USB port at an upward angle from below.
- Press the PROGRAM EDIT key, then select External I/O (F3) → Maintenance (F3).
- If necessary, select Disk Format and execute Format (F2).
Formatting is not required if the USB memory device does not contain data of the same format and has sufficient available storage capacity. - Return to the previous screen (F0), then select All Data Output (F1) → Output (F2).
- Wait until the data output process is completed. Do not perform any operations during the process, and confirm that the Normal End screen is displayed.
- Press the RESET button to return to the Manual Conditions screen, then remove the USB memory device by pulling it downward at an angle.
- Connect the USB memory device to a computer and verify that the data has been saved successfully.
- Store the backup data either by:
・Creating a separate folder for each machine on a computer and saving the data there, or
・Keeping the USB memory device as a dedicated backup device for that machine.
Estimated time required: Approximately 10 minutes.
View details(PDF 2.3MB)
-
mt-005
Mist Separator Filter Replacement Procedure
-
This procedure describes how to inspect and replace the filter inside the mist separator.
- Turn the valve to shut off the air supply pressure.
WARNING
Disassembling the mist separator without shutting off the air supply pressure is hazardous, as compressed air may be released by the internal pressure.[Power ON Prohibited] [Air Supply OFF] - Remove the four M5 hex socket head cap screws and disassemble the mist separator.[Wear Protective Gloves]
- Inspect the two gasket types located on the underside of the cover. If either gasket is damaged or deteriorated, replace it with a new one.
Continued use of damaged gaskets may result in air leakage or machine malfunction. - Remove the filter and replace it with a new one.
Be sure to replace the filter if it shows signs of discoloration or hardening. Install the filter with the perforated side facing upward. - Reassemble the mist separator with the viewing window facing toward the front of the machine, and secure it using the four M5 hex socket head cap screws.
Tightening torque: 6.86 N·m.
View details(PDF 1MB)
- Turn the valve to shut off the air supply pressure.
-
mt-006
SX seires daily monthly inspection
-
For detailed information on the SX Series Daily Monthly Inspection, refer to the video below.
-
mt-007
RX seires daily monthly inspection
-
For detailed information on the RX Series Daily Monthly Inspection, refer to the video below.
-
mt-008
MX seires daily monthly inspection
-
For detailed information on the MX Series Daily Monthly Inspection, refer to the video below.
-
mt-009
D00 Full Data Input Procedure
-
This procedure explains how to input (restore) all data for the D00 control. Use it as part of your regular maintenance activities.
Install a USB memory device into the operation panel and perform the All Data Maintenance settings and data input operation. After the procedure is complete, remove the USB memory device, cycle the power OFF and ON, and verify proper machine operation.
View details(PDF 4.4MB)
-
mt-010
Suction Filter Replacement Procedure
-
For detailed information on the Suction Filter Replacement Procedure, refer to the PDF below.
View details(PDF 1.6MB)
-
mt-011
How to Use an Insulation Resistance Tester
-
For detailed information on How to Use an Insulation Resistance Tester, refer to the PDF below.
View details(PDF 1MB)
-
mt-012
M-Series Chip Conveyor and Coolant Tank Cleaning Procedure
-
This procedure explains how to clean the chip conveyor and coolant tank. Use it as part of your regular maintenance activities.
The hinge scraper-type chip conveyor separates and collects chips using hinges and scrapers. Regular cleaning is essential to prevent clogging of the PD filter and other filters.
Routine removal of accumulated chips, cleaning of filters, and inspection and cleaning of the coolant tank help prevent machine problems and ensure stable machine operation.
View details(PDF 1.8MB)